Report Suspicious Activity
Overview

Landfill gas analysis systems are the best tool for assisting you:

 

To check whether the gas is still being produced

To decide when the land can be reclaimed

To check the produced gas quality prior to use in industrial process

To continuously monitor the efficiency of H2S scrubber installation.

 

 

 

Wall-mount IP54 stainless steel panel for outdoor installation

  1. Mechanical Specifications
  • Dimensions: H700 x W450 xD220 mm
  • Material: Stainless Steel, plate thick 2mm
  • 4 brackets for wall mounting
  • Hinged front door with visualization
  • Window (255 x 100mm), with handle
  • Door clamping with 6 bolts M8
  • Internal compartment for Biogas Analyzer

 

  1. Environmental Conditions
  • Operating temperature range: -15°C to +45°C
  • Operating humidity range: 0-95% RH non condensing
  • Operating pressure range: 800-1200 hPa

 

  1. Pneumatic Specifications
  • Stainless Steel connector for gas inlet, gas outlet, zero air inlet and drain ports
  • Manual valve for measure/ calibration selection
  • Flow meter

 

  1. Gas sampling and conditioning (Accessible via the internal access front door)
  • Pre-filtration by coalescing filter with peristaltic pump for continuous condensate removal
  • Built-in heater avoid water condensate block the pipe in the winter

 

Four Gases Analyzer for Biogas Process Monitoring

Gas

Symbol

Technology

Range

Resolution

Accuracy

T90

Oxygen

O2

Fuel Cell

0-25% Vol.

0.01%

±2% FS

< 15s

Carbon Dioxide

CO2

NDIR

0-50% Vol.

0.01%

±2% FS

< 10s

Methane

CH4

NDIR

0-100% Vol.

0.1%

±2% FS

< 10s

Hydrogen Sulphide

H2S

Electrochemical Cell

0-9999 ppm

1ppm

±3% FS

< 30s